文章详情

ID: 7235
实例类型: faq
分类:
相关:
产品系列: CertusPro-NX

搜索答案数据库

Search Text Image

Lattice Radiant: What does this warning mean "Generated_clock: not connect to any master clock pin."?

Description:
The user encounters a WARNING message shown below whenever they utilize a PLL IP. 

"Generated_clock: not connect to any master clock pin."

Solution:
The warning implies that the timing engine is indicating that there is no clock at the source pin. The user needs to define a clock on the port that drives the reference pin of the PLL.

At Radiant 2023.2 or later, the message will be changed from "Generated_clock: not connected to any master clock pin." to "Generated_clock: clock not found on source pin.".