文章详情

ID: 7171
实例类型: faq
分类: Programming and Configuration
相关:
产品系列: CrossLink-NX

搜索答案数据库

Search Text Image

All Nexus: Unable to re-program Nexus devices more than once without power cycling the device. At DCE, bank VCCIO is set to "AUTO

Description:

In the Device Constraint Editor, it is recommended that the actual voltage must be reflected on VCCIO/CONFIGIO banks.
The default "AUTO" in VCCIO Bank setting is equivalent to 3.3V, and CONFIGIO_VOLTAGE_BANK0/1 = NOT_SPECIFIED
If actual Voltage level is less than 3.3V, say 1.8V, then there will be a logic level mismatch that will cause unsuccessful reconfiguration
Please refer to FPGA-TN-02099 under CONFIGIO_VOLTAGE_BANK0/CONFIGIO_VOLTAGE_BANK1 section for more details.

Solution:
Set Actual Voltage level on the Global Device Constraint Editor under CONFIGIO_VOLTAGE_BANK0/1 parameter.