MPCS IP: Can the equalization algorithm of the MPCS IP module be selected through the LMMI dynamically?

This can be done dynamically using LMMI (Lattice Memory Mapped Interface).

The user just has to write the register address value (\u2018d217) to the lmmi_offset_i (address/offset) to access that PMA register.

The needed information are shown below:

Register address: 'D217

Register Name: REG217- Equalization Register
Default values: 'h7C

rxeq_enable[2:0] of REG217[2:0]: This register enables to perform adaptive equalization in each data rate:

 - rxeq_enable[0]: gen1 data rate

 - rxeq_enable[1]: gen2 data rate

 - rxeq_enable[2]: gen3 data rate

rxeq_algo[2:0] of REG217[6:4]: This register defines which equalization algorithm to apply in each data rate:

 - 000: SS_LMS

 - 001:RL2plus

for example:

If RL2plus is desire & gen1 data rate:

lmmi_offset_i = 217

lmmi_wdata_i = 16'h1C

Then to change it to SS_LMS dynamically, provide another write to the register:

lmmi_offset_i = 217

lmmi_wdata_i = 16'h0C