Description:
MIPI CSI2 RX interface RD1146 was the first to be introduced and the termination scheme used for that was using HSTL18 for the LP signals.
The D-Phy(RD1182) was introduced later and the termination scheme optimized and superseded the termination scheme and IO Standard for the LP signals. Both work and you could use either of the two.